Change orders
73 change orders across 12 projects
Approved
$723k
57 change orders added to contract
Pending with owners
$172k
12 submitted, awaiting a decision
Value at risk
$158k
6 being built without an approved change order
Longest unresolved
84 days
RCG-2482 CO-003 · Relocate roof curbs to clear structure
Average time to decision
25 days
on change orders the owners have decided
$157,927 of change order work is in progress or complete without a signed change order. The cost is already in the job cost forecast on every one of these projects. None of the revenue is in a contract. Every day one of these sits undecided, the argument gets harder to win.
73 of 73 change orders
| Description | Submitted | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| CO-014 | RCG-2451Beacon Health Medical Office … | Abandoned pneumatic tube system and non-conforming duct, L2 plenum | Unforeseen Condition | Work Proceeding — Unapproved | 86,400 | 96,768 | 9d | 24 Jul 26 | 47 |
| CO-003 | RCG-2487Trailhead Coffee Roasters Fit… | Grease exhaust shaft enclosure omitted from permit set | Design Error / Omission | Work Proceeding — Unapproved | 14,200 | 15,904 | 11d | 27 Jul 26 | 44 |
| CO-002 | RCG-2470Grayson Industrial Park — Bui… | Credit — delete decorative screen wall | Owner Request | Submitted to Owner | (25,150) | (28,922) | — | 17 Jun 26 | 84 |
| CO-003 | RCG-2482Cedar Bluff Urgent Care | Relocate roof curbs to clear structure | Field Coordination | Submitted to Owner | 5,950 | 6,842 | 2d | 17 Jun 26 | 84 |
| CO-007 | RCG-2402Willow Court Retail Center Sh… | Backflow preventer and enclosure required by water authority | Regulatory / AHJ | Submitted to Owner | 10,250 | 11,275 | 2d | 02 Jul 26 | 69 |
| CO-011 | RCG-2451Beacon Health Medical Office … | Condensate drainage for six fan coil units | Design Error / Omission | Submitted to Owner | 12,400 | 13,640 | 2d | 09 Jul 26 | 62 |
| CO-003 | RCG-2470Grayson Industrial Park — Bui… | Add break room casework and appliance rough-ins | Owner Request | Submitted to Owner | 15,850 | 18,228 | — | 19 Jul 26 | 52 |
| CO-010 | RCG-2451Beacon Health Medical Office … | Level 1 lobby flooring — porcelain tile in lieu of LVT | Owner Request | Submitted to Owner | 26,900 | 30,935 | — | 07 Aug 26 | 33 |
| CO-005 | RCG-2482Cedar Bluff Urgent Care | Missing roof drain overflow scuppers | Design Error / Omission | Submitted to Owner | 5,950 | 6,545 | 2d | 15 Aug 26 | 25 |
| CO-001 | RCG-2495Anchor Point Distribution — P… | Existing slab thinner than record drawings | Unforeseen Condition | Submitted to Owner | 24,900 | 28,635 | 3d | 18 Aug 26 | 22 |
| CO-002 | RCG-2478Kestrel Logistics Warehouse S… | Credit — delete decorative screen wall | Owner Request | Submitted to Owner | (25,700) | (29,555) | — | 21 Aug 26 | 19 |
| CO-001 | RCG-2492Northgate Vision Center TI | Omitted expansion joint at slab transition | Design Error / Omission | Submitted to Owner | 1,450 | 1,595 | 1d | 22 Aug 26 | 18 |
| CO-015 | RCG-2451Beacon Health Medical Office … | Access panels at 14 VAV and valve locations | Field Coordination | Draft | 7,300 | 8,395 | — | not submitted | 7 |
| CO-005 | RCG-2487Trailhead Coffee Roasters Fit… | Added mural wall blocking and lighting, seating area | Owner Request | Draft | 3,400 | 3,910 | — | not submitted | 5 |
| CO-002 | RCG-2465Summit Orthopedic Surgery Cen… | Omitted expansion joint at slab transition | Design Error / Omission | Approved | 7,750 | 8,525 | 1d | 07 Feb 26 | 44 |
| CO-008 | RCG-2465Summit Orthopedic Surgery Cen… | Undersized service feeder revision | Design Error / Omission | Approved | 20,600 | 22,660 | 4d | 03 Jun 26 | 44 |
| CO-002 | RCG-2482Cedar Bluff Urgent Care | Duct and sprinkler main conflict above corridor | Field Coordination | Approved | 4,400 | 5,060 | 1d | 13 Jun 26 | 44 |
| CO-004 | RCG-2390Fairhaven Dental Group TI | Omitted expansion joint at slab transition | Design Error / Omission | Approved | 3,800 | 4,180 | 1d | 09 Mar 26 | 42 |
| CO-006 | RCG-2390Fairhaven Dental Group TI | Upgrade restroom finishes to porcelain tile | Owner Request | Approved | 7,300 | 8,395 | 2d | 26 May 26 | 42 |
| CO-002 | RCG-2455Marlow Crossing Retail Center | Upgrade restroom finishes to porcelain tile | Owner Request | Approved | 11,100 | 12,765 | 2d | 01 Feb 26 | 41 |
| CO-002 | RCG-2492Northgate Vision Center TI | Credit — reduce site lighting pole count | Owner Request | Approved | (1,850) | (2,127) | — | 02 Sep 26 | 41 |
| CO-005 | RCG-2455Marlow Crossing Retail Center | Deteriorated existing roof deck | Unforeseen Condition | Approved | 14,350 | 16,503 | 4d | 04 Jun 26 | 40 |
| CO-007 | RCG-2465Summit Orthopedic Surgery Cen… | Backflow preventer and enclosure required by water authority | Regulatory / AHJ | Approved | 13,500 | 14,850 | 2d | 30 May 26 | 39 |
| CO-005 | RCG-2402Willow Court Retail Center Sh… | Credit — delete decorative screen wall | Owner Request | Approved | (9,250) | (10,637) | — | 28 Mar 26 | 38 |
| CO-005 | RCG-2447Redstone Self-Storage Convers… | Add exterior wall pack lighting at loading area | Owner Request | Approved | 3,750 | 4,313 | — | 22 Jun 26 | 38 |
| CO-005 | RCG-2390Fairhaven Dental Group TI | Structural connection revision at canopy | Design Error / Omission | Approved | 6,700 | 7,370 | 3d | 01 Apr 26 | 36 |
| CO-005 | RCG-2465Summit Orthopedic Surgery Cen… | Structural connection revision at canopy | Design Error / Omission | Approved | 19,650 | 21,615 | 3d | 24 Apr 26 | 36 |
| CO-004 | RCG-2470Grayson Industrial Park — Bui… | Add exterior wall pack lighting at loading area | Owner Request | Approved | 19,600 | 22,540 | — | 11 Aug 26 | 35 |
| CO-006 | RCG-2402Willow Court Retail Center Sh… | Undocumented utility line in trench alignment | Unforeseen Condition | Approved | 11,900 | 13,685 | 5d | 03 Apr 26 | 34 |
| CO-008 | RCG-2402Willow Court Retail Center Sh… | Duct and sprinkler main conflict above corridor | Field Coordination | Approved | 14,700 | 16,905 | 1d | 07 Jul 26 | 33 |
| CO-001 | RCG-2478Kestrel Logistics Warehouse S… | Add access panels at valve and damper locations | Field Coordination | Approved | 12,550 | 14,432 | — | 25 Jul 26 | 32 |
| CO-001 | RCG-2390Fairhaven Dental Group TI | Add access panels at valve and damper locations | Field Coordination | Approved | 2,000 | 2,300 | — | 25 Dec 25 | 30 |
| CO-001 | RCG-2455Marlow Crossing Retail Center | Add break room casework and appliance rough-ins | Owner Request | Approved | 10,350 | 11,902 | — | 27 Jan 26 | 29 |
| CO-004 | RCG-2465Summit Orthopedic Surgery Cen… | Upgrade restroom finishes to porcelain tile | Owner Request | Approved | 19,700 | 22,655 | 2d | 01 Apr 26 | 28 |
| CO-004 | RCG-2455Marlow Crossing Retail Center | Fire marshal comment — additional exit signage and egress lighting | Regulatory / AHJ | Approved | 7,000 | 7,700 | 1d | 15 Mar 26 | 28 |
| CO-003 | RCG-2465Summit Orthopedic Surgery Cen… | Deteriorated existing roof deck | Unforeseen Condition | Approved | 24,050 | 27,657 | 4d | 19 Feb 26 | 27 |
| CO-003 | RCG-2478Kestrel Logistics Warehouse S… | Structural connection revision at canopy | Design Error / Omission | Approved | 30,750 | 33,825 | 3d | 22 Aug 26 | 26 |
| CO-002 | RCG-2402Willow Court Retail Center Sh… | Accessibility corrections at entry landing | Regulatory / AHJ | Approved | 7,850 | 8,635 | 3d | 28 Dec 25 | 26 |
| CO-001 | RCG-2482Cedar Bluff Urgent Care | Add access panels at valve and damper locations | Field Coordination | Approved | 2,000 | 2,300 | — | 30 May 26 | 26 |
| CO-005 | RCG-2470Grayson Industrial Park — Bui… | Upgrade restroom finishes to porcelain tile | Owner Request | Approved | 35,150 | 40,423 | 2d | 17 Aug 26 | 25 |
| CO-006 | RCG-2465Summit Orthopedic Surgery Cen… | Add access panels at valve and damper locations | Field Coordination | Approved | 7,300 | 8,395 | — | 19 May 26 | 24 |
| CO-002 | RCG-2447Redstone Self-Storage Convers… | Deteriorated existing roof deck | Unforeseen Condition | Approved | 4,550 | 5,233 | 4d | 25 Mar 26 | 23 |
| CO-003 | RCG-2447Redstone Self-Storage Convers… | Structural connection revision at canopy | Design Error / Omission | Approved | 4,500 | 4,950 | 3d | 05 Jun 26 | 23 |
| CO-006 | RCG-2447Redstone Self-Storage Convers… | Fire marshal comment — additional exit signage and egress lighting | Regulatory / AHJ | Approved | 2,750 | 3,025 | 1d | 29 Jun 26 | 23 |
| CO-002 | RCG-2451Beacon Health Medical Office … | Fire-rated ceiling assembly, Corridor C2 (ASI-014) | Design Error / Omission | Approved | 24,800 | 27,280 | 3d | 04 May 26 | 22 |
| CO-008 | RCG-2451Beacon Health Medical Office … | Two additional Level 2 sub-panels (revised panel schedule) | Design Error / Omission | Approved | 19,700 | 21,670 | 3d | 29 Jun 26 | 21 |
| CO-002 | RCG-2390Fairhaven Dental Group TI | Credit — reduce site lighting pole count | Owner Request | Approved | (4,800) | (5,520) | — | 29 Dec 25 | 20 |
| CO-001 | RCG-2447Redstone Self-Storage Convers… | Existing slab thinner than record drawings | Unforeseen Condition | Approved | 5,150 | 5,922 | 3d | 22 Mar 26 | 20 |
| CO-004 | RCG-2451Beacon Health Medical Office … | AHJ-required smoke dampers at six corridor penetrations | Regulatory / AHJ | Approved | 16,200 | 17,820 | 2d | 14 May 26 | 19 |
| CO-012 | RCG-2451Beacon Health Medical Office … | Sprinkler main reroute at Level 2 imaging | Field Coordination | Approved | 9,600 | 11,040 | 1d | 31 Jul 26 | 19 |
| CO-006 | RCG-2455Marlow Crossing Retail Center | Undersized service feeder revision | Design Error / Omission | Approved | 11,800 | 12,980 | 4d | 08 Jul 26 | 19 |
| CO-005 | RCG-2451Beacon Health Medical Office … | Solid surface upgrade, Level 2 nurse station | Owner Request | Approved | 22,600 | 25,990 | — | 04 Jun 26 | 18 |
| CO-006 | RCG-2451Beacon Health Medical Office … | Relocate 4 in. sanitary line at imaging equipment pad | Field Coordination | Approved | 8,750 | 10,063 | 1d | 21 May 26 | 18 |
| CO-007 | RCG-2451Beacon Health Medical Office … | Badge readers and door position switches at nine openings | Owner Request | Approved | 31,400 | 36,110 | — | 18 Jun 26 | 18 |
| CO-001 | RCG-2402Willow Court Retail Center Sh… | Structural connection revision at canopy | Design Error / Omission | Approved | 17,850 | 19,635 | 3d | 26 Dec 25 | 18 |
| CO-003 | RCG-2455Marlow Crossing Retail Center | Omitted expansion joint at slab transition | Design Error / Omission | Approved | 5,800 | 6,380 | 1d | 28 Feb 26 | 18 |
| CO-009 | RCG-2465Summit Orthopedic Surgery Cen… | Duct and sprinkler main conflict above corridor | Field Coordination | Approved | 10,800 | 12,420 | 1d | 19 Jun 26 | 17 |
| CO-003 | RCG-2390Fairhaven Dental Group TI | Additional power and data at open office | Owner Request | Approved | 5,400 | 6,210 | — | 23 Feb 26 | 16 |
| CO-003 | RCG-2451Beacon Health Medical Office … | Slab depression at abandoned chase, Level 1 | Unforeseen Condition | Approved | 11,900 | 13,685 | 2d | 09 Apr 26 | 15 |
| CO-001 | RCG-2487Trailhead Coffee Roasters Fit… | Landlord-required electrical panel relocation | Owner Request | Approved | 9,800 | 11,270 | 3d | 11 Jun 26 | 15 |
| CO-001 | RCG-2451Beacon Health Medical Office … | Casework and hand sinks, Exam 214–218 | Owner Request | Approved | 18,400 | 21,160 | — | 17 Apr 26 | 14 |
| CO-009 | RCG-2451Beacon Health Medical Office … | Mastic abatement under existing VCT, Suite 240 | Unforeseen Condition | Approved | 14,300 | 16,445 | 4d | 01 Apr 26 | 14 |
| CO-013 | RCG-2451Beacon Health Medical Office … | Credit — delete two exam room sinks, Suite 260 | Owner Request | Approved | (6,800) | (7,820) | — | 15 Jul 26 | 14 |
| CO-002 | RCG-2487Trailhead Coffee Roasters Fit… | Floor sink and indirect waste at espresso bar | Regulatory / AHJ | Approved | 4,600 | 5,290 | 1d | 24 Jun 26 | 14 |
| CO-007 | RCG-2455Marlow Crossing Retail Center | Undocumented utility line in trench alignment | Unforeseen Condition | Approved | 11,500 | 13,225 | 5d | 20 Jul 26 | 14 |
| CO-004 | RCG-2402Willow Court Retail Center Sh… | Fire marshal comment — additional exit signage and egress lighting | Regulatory / AHJ | Approved | 7,300 | 8,030 | 1d | 19 Mar 26 | 13 |
| CO-001 | RCG-2470Grayson Industrial Park — Bui… | Undersized service feeder revision | Design Error / Omission | Approved | 41,000 | 45,100 | 4d | 15 Jun 26 | 13 |
| CO-003 | RCG-2402Willow Court Retail Center Sh… | Relocate roof curbs to clear structure | Field Coordination | Approved | 13,500 | 15,525 | 2d | 07 Feb 26 | 12 |
| CO-004 | RCG-2487Trailhead Coffee Roasters Fit… | Storefront door hardware upgrade to panic device | Regulatory / AHJ | Approved | 2,900 | 3,335 | — | 02 Jul 26 | 12 |
| CO-004 | RCG-2482Cedar Bluff Urgent Care | Omitted expansion joint at slab transition | Design Error / Omission | Approved | 4,150 | 4,565 | 1d | 27 Jun 26 | 12 |
| CO-004 | RCG-2447Redstone Self-Storage Convers… | Upgrade restroom finishes to porcelain tile | Owner Request | Approved | 4,650 | 5,348 | 2d | 06 Jun 26 | 12 |
| CO-001 | RCG-2465Summit Orthopedic Surgery Cen… | Upgrade to LED high-bay fixtures | Owner Request | Rejected | 10,450 | 12,017 | — | 31 Jan 26 | 30 |
| CO-016 | RCG-2451Beacon Health Medical Office … | Additional data drops, Suites 210 and 220 | Owner Request | Rejected | 5,900 | 6,785 | — | 11 Jun 26 | 19 |
| Total — 73 change orders | 821,200 | 926,189 | of which 157,927 is at risk | ||||||