73 change orders across 12 projects

Approved
$723k
57 change orders added to contract
Pending with owners
$172k
12 submitted, awaiting a decision
Value at risk
$158k
6 being built without an approved change order
Longest unresolved
84 days
RCG-2482 CO-003 · Relocate roof curbs to clear structure
Average time to decision
25 days
on change orders the owners have decided

$157,927 of change order work is in progress or complete without a signed change order. The cost is already in the job cost forecast on every one of these projects. None of the revenue is in a contract. Every day one of these sits undecided, the argument gets harder to win.

73 of 73 change orders
DescriptionSubmitted
CO-014RCG-2451Beacon Health Medical Office …Abandoned pneumatic tube system and non-conforming duct, L2 plenumUnforeseen ConditionWork Proceeding — Unapproved86,40096,7689d24 Jul 2647
CO-003RCG-2487Trailhead Coffee Roasters Fit…Grease exhaust shaft enclosure omitted from permit setDesign Error / OmissionWork Proceeding — Unapproved14,20015,90411d27 Jul 2644
CO-002RCG-2470Grayson Industrial Park — Bui…Credit — delete decorative screen wallOwner RequestSubmitted to Owner(25,150)(28,922)17 Jun 2684
CO-003RCG-2482Cedar Bluff Urgent CareRelocate roof curbs to clear structureField CoordinationSubmitted to Owner5,9506,8422d17 Jun 2684
CO-007RCG-2402Willow Court Retail Center Sh…Backflow preventer and enclosure required by water authorityRegulatory / AHJSubmitted to Owner10,25011,2752d02 Jul 2669
CO-011RCG-2451Beacon Health Medical Office …Condensate drainage for six fan coil unitsDesign Error / OmissionSubmitted to Owner12,40013,6402d09 Jul 2662
CO-003RCG-2470Grayson Industrial Park — Bui…Add break room casework and appliance rough-insOwner RequestSubmitted to Owner15,85018,22819 Jul 2652
CO-010RCG-2451Beacon Health Medical Office …Level 1 lobby flooring — porcelain tile in lieu of LVTOwner RequestSubmitted to Owner26,90030,93507 Aug 2633
CO-005RCG-2482Cedar Bluff Urgent CareMissing roof drain overflow scuppersDesign Error / OmissionSubmitted to Owner5,9506,5452d15 Aug 2625
CO-001RCG-2495Anchor Point Distribution — P…Existing slab thinner than record drawingsUnforeseen ConditionSubmitted to Owner24,90028,6353d18 Aug 2622
CO-002RCG-2478Kestrel Logistics Warehouse S…Credit — delete decorative screen wallOwner RequestSubmitted to Owner(25,700)(29,555)21 Aug 2619
CO-001RCG-2492Northgate Vision Center TIOmitted expansion joint at slab transitionDesign Error / OmissionSubmitted to Owner1,4501,5951d22 Aug 2618
CO-015RCG-2451Beacon Health Medical Office …Access panels at 14 VAV and valve locationsField CoordinationDraft7,3008,395not submitted7
CO-005RCG-2487Trailhead Coffee Roasters Fit…Added mural wall blocking and lighting, seating areaOwner RequestDraft3,4003,910not submitted5
CO-002RCG-2465Summit Orthopedic Surgery Cen…Omitted expansion joint at slab transitionDesign Error / OmissionApproved7,7508,5251d07 Feb 2644
CO-008RCG-2465Summit Orthopedic Surgery Cen…Undersized service feeder revisionDesign Error / OmissionApproved20,60022,6604d03 Jun 2644
CO-002RCG-2482Cedar Bluff Urgent CareDuct and sprinkler main conflict above corridorField CoordinationApproved4,4005,0601d13 Jun 2644
CO-004RCG-2390Fairhaven Dental Group TIOmitted expansion joint at slab transitionDesign Error / OmissionApproved3,8004,1801d09 Mar 2642
CO-006RCG-2390Fairhaven Dental Group TIUpgrade restroom finishes to porcelain tileOwner RequestApproved7,3008,3952d26 May 2642
CO-002RCG-2455Marlow Crossing Retail CenterUpgrade restroom finishes to porcelain tileOwner RequestApproved11,10012,7652d01 Feb 2641
CO-002RCG-2492Northgate Vision Center TICredit — reduce site lighting pole countOwner RequestApproved(1,850)(2,127)02 Sep 2641
CO-005RCG-2455Marlow Crossing Retail CenterDeteriorated existing roof deckUnforeseen ConditionApproved14,35016,5034d04 Jun 2640
CO-007RCG-2465Summit Orthopedic Surgery Cen…Backflow preventer and enclosure required by water authorityRegulatory / AHJApproved13,50014,8502d30 May 2639
CO-005RCG-2402Willow Court Retail Center Sh…Credit — delete decorative screen wallOwner RequestApproved(9,250)(10,637)28 Mar 2638
CO-005RCG-2447Redstone Self-Storage Convers…Add exterior wall pack lighting at loading areaOwner RequestApproved3,7504,31322 Jun 2638
CO-005RCG-2390Fairhaven Dental Group TIStructural connection revision at canopyDesign Error / OmissionApproved6,7007,3703d01 Apr 2636
CO-005RCG-2465Summit Orthopedic Surgery Cen…Structural connection revision at canopyDesign Error / OmissionApproved19,65021,6153d24 Apr 2636
CO-004RCG-2470Grayson Industrial Park — Bui…Add exterior wall pack lighting at loading areaOwner RequestApproved19,60022,54011 Aug 2635
CO-006RCG-2402Willow Court Retail Center Sh…Undocumented utility line in trench alignmentUnforeseen ConditionApproved11,90013,6855d03 Apr 2634
CO-008RCG-2402Willow Court Retail Center Sh…Duct and sprinkler main conflict above corridorField CoordinationApproved14,70016,9051d07 Jul 2633
CO-001RCG-2478Kestrel Logistics Warehouse S…Add access panels at valve and damper locationsField CoordinationApproved12,55014,43225 Jul 2632
CO-001RCG-2390Fairhaven Dental Group TIAdd access panels at valve and damper locationsField CoordinationApproved2,0002,30025 Dec 2530
CO-001RCG-2455Marlow Crossing Retail CenterAdd break room casework and appliance rough-insOwner RequestApproved10,35011,90227 Jan 2629
CO-004RCG-2465Summit Orthopedic Surgery Cen…Upgrade restroom finishes to porcelain tileOwner RequestApproved19,70022,6552d01 Apr 2628
CO-004RCG-2455Marlow Crossing Retail CenterFire marshal comment — additional exit signage and egress lightingRegulatory / AHJApproved7,0007,7001d15 Mar 2628
CO-003RCG-2465Summit Orthopedic Surgery Cen…Deteriorated existing roof deckUnforeseen ConditionApproved24,05027,6574d19 Feb 2627
CO-003RCG-2478Kestrel Logistics Warehouse S…Structural connection revision at canopyDesign Error / OmissionApproved30,75033,8253d22 Aug 2626
CO-002RCG-2402Willow Court Retail Center Sh…Accessibility corrections at entry landingRegulatory / AHJApproved7,8508,6353d28 Dec 2526
CO-001RCG-2482Cedar Bluff Urgent CareAdd access panels at valve and damper locationsField CoordinationApproved2,0002,30030 May 2626
CO-005RCG-2470Grayson Industrial Park — Bui…Upgrade restroom finishes to porcelain tileOwner RequestApproved35,15040,4232d17 Aug 2625
CO-006RCG-2465Summit Orthopedic Surgery Cen…Add access panels at valve and damper locationsField CoordinationApproved7,3008,39519 May 2624
CO-002RCG-2447Redstone Self-Storage Convers…Deteriorated existing roof deckUnforeseen ConditionApproved4,5505,2334d25 Mar 2623
CO-003RCG-2447Redstone Self-Storage Convers…Structural connection revision at canopyDesign Error / OmissionApproved4,5004,9503d05 Jun 2623
CO-006RCG-2447Redstone Self-Storage Convers…Fire marshal comment — additional exit signage and egress lightingRegulatory / AHJApproved2,7503,0251d29 Jun 2623
CO-002RCG-2451Beacon Health Medical Office …Fire-rated ceiling assembly, Corridor C2 (ASI-014)Design Error / OmissionApproved24,80027,2803d04 May 2622
CO-008RCG-2451Beacon Health Medical Office …Two additional Level 2 sub-panels (revised panel schedule)Design Error / OmissionApproved19,70021,6703d29 Jun 2621
CO-002RCG-2390Fairhaven Dental Group TICredit — reduce site lighting pole countOwner RequestApproved(4,800)(5,520)29 Dec 2520
CO-001RCG-2447Redstone Self-Storage Convers…Existing slab thinner than record drawingsUnforeseen ConditionApproved5,1505,9223d22 Mar 2620
CO-004RCG-2451Beacon Health Medical Office …AHJ-required smoke dampers at six corridor penetrationsRegulatory / AHJApproved16,20017,8202d14 May 2619
CO-012RCG-2451Beacon Health Medical Office …Sprinkler main reroute at Level 2 imagingField CoordinationApproved9,60011,0401d31 Jul 2619
CO-006RCG-2455Marlow Crossing Retail CenterUndersized service feeder revisionDesign Error / OmissionApproved11,80012,9804d08 Jul 2619
CO-005RCG-2451Beacon Health Medical Office …Solid surface upgrade, Level 2 nurse stationOwner RequestApproved22,60025,99004 Jun 2618
CO-006RCG-2451Beacon Health Medical Office …Relocate 4 in. sanitary line at imaging equipment padField CoordinationApproved8,75010,0631d21 May 2618
CO-007RCG-2451Beacon Health Medical Office …Badge readers and door position switches at nine openingsOwner RequestApproved31,40036,11018 Jun 2618
CO-001RCG-2402Willow Court Retail Center Sh…Structural connection revision at canopyDesign Error / OmissionApproved17,85019,6353d26 Dec 2518
CO-003RCG-2455Marlow Crossing Retail CenterOmitted expansion joint at slab transitionDesign Error / OmissionApproved5,8006,3801d28 Feb 2618
CO-009RCG-2465Summit Orthopedic Surgery Cen…Duct and sprinkler main conflict above corridorField CoordinationApproved10,80012,4201d19 Jun 2617
CO-003RCG-2390Fairhaven Dental Group TIAdditional power and data at open officeOwner RequestApproved5,4006,21023 Feb 2616
CO-003RCG-2451Beacon Health Medical Office …Slab depression at abandoned chase, Level 1Unforeseen ConditionApproved11,90013,6852d09 Apr 2615
CO-001RCG-2487Trailhead Coffee Roasters Fit…Landlord-required electrical panel relocationOwner RequestApproved9,80011,2703d11 Jun 2615
CO-001RCG-2451Beacon Health Medical Office …Casework and hand sinks, Exam 214–218Owner RequestApproved18,40021,16017 Apr 2614
CO-009RCG-2451Beacon Health Medical Office …Mastic abatement under existing VCT, Suite 240Unforeseen ConditionApproved14,30016,4454d01 Apr 2614
CO-013RCG-2451Beacon Health Medical Office …Credit — delete two exam room sinks, Suite 260Owner RequestApproved(6,800)(7,820)15 Jul 2614
CO-002RCG-2487Trailhead Coffee Roasters Fit…Floor sink and indirect waste at espresso barRegulatory / AHJApproved4,6005,2901d24 Jun 2614
CO-007RCG-2455Marlow Crossing Retail CenterUndocumented utility line in trench alignmentUnforeseen ConditionApproved11,50013,2255d20 Jul 2614
CO-004RCG-2402Willow Court Retail Center Sh…Fire marshal comment — additional exit signage and egress lightingRegulatory / AHJApproved7,3008,0301d19 Mar 2613
CO-001RCG-2470Grayson Industrial Park — Bui…Undersized service feeder revisionDesign Error / OmissionApproved41,00045,1004d15 Jun 2613
CO-003RCG-2402Willow Court Retail Center Sh…Relocate roof curbs to clear structureField CoordinationApproved13,50015,5252d07 Feb 2612
CO-004RCG-2487Trailhead Coffee Roasters Fit…Storefront door hardware upgrade to panic deviceRegulatory / AHJApproved2,9003,33502 Jul 2612
CO-004RCG-2482Cedar Bluff Urgent CareOmitted expansion joint at slab transitionDesign Error / OmissionApproved4,1504,5651d27 Jun 2612
CO-004RCG-2447Redstone Self-Storage Convers…Upgrade restroom finishes to porcelain tileOwner RequestApproved4,6505,3482d06 Jun 2612
CO-001RCG-2465Summit Orthopedic Surgery Cen…Upgrade to LED high-bay fixturesOwner RequestRejected10,45012,01731 Jan 2630
CO-016RCG-2451Beacon Health Medical Office …Additional data drops, Suites 210 and 220Owner RequestRejected5,9006,78511 Jun 2619
Total — 73 change orders821,200926,189of which 157,927 is at risk